Ireland Roller Shutters offer 2, 3 and 4 hour rated Fire Shutters. All products are fully tested, approved and manufactured.
Please note that we manufacture Single and Twin Skin Lath Fire Rated Roller Shutters tested to Exova Fire and Safety BSEN 1634-1 and providing up to 4 Hours of fire resistance. The Double Skin Insulated Lath offers additional heat radiation protection.
Exova Warrington Fire is part of Exova, the world’s largest dedicated testing group, trusted by organisations to test and advise on the safety, quality and performance of their products and operators. Exova’s capabililites help to extend asset life, bring predictability to applications and shorten the time to market for clients products, processes and materials.
With over 40 years experience, Exova specialises in testing across nine key sectors from food and pharmaceuticals to aerospace, oil and gas, fire, engineering and construction.
Exova operates 110 permanent facilites in 22 countries and employs more than 3500 people throughout Europe, North Amercia, South Amercia, The Middle East and Asia.
Atex Certified Motors available in our Fire Shutters.
As part of our ongoing commitment to provide clients with a complete range of security options, we are now able to offer Fire Curtains and Smoke Curtains. Please call for details.
Please note we offer supply only to anywhere in Ireland and delivery we do not install!
Tel: 00 44 161 272 9333
Fire Shutters are a increasingly popular security product and offer fire protection at up to four hours greater than would be the case for a standard door or shutter. They can be used to portion off and protect a particular part of a building, the whole building, or even provide protection between floors (horizontal fire shutters).
There are three main methods of automatic operation. A fusible link involves the use of solder as connection in the circuit: heat radiated from a nearby fire causes the solder to melt and this activates the door.
A Fire Relay means that the shutter or door is connected to the fire alarm system: when the alarm is sounded, the shutter or door activates. Finally, a delayed Audio/Visual Warning used in connection with the Shutter is connected to the alarm system, and operates usually with a time delay very similarly to a fire relay. During this delay an additional alarm is sounded, warning those in close proximity to the door that is about to close, thus allowing them to exit the affected area.
Ireland Fire Shutters
Fire Shutters help many businesses to ensure that they protect their goods, buildings and employees from the threat of fire by offering potentially significant delays to the spread of fire.
If you are a business owner and take the security and safety of your business, premises and staff seriously, you may be surprised to know that every year many businesses are forced to close as insurance companies often refuse to meet claims because building regulations and Loss Prevention Council requirements have not been met in relation to fire spread.
Building regulations require that openings in fire resisting walls or partitions must have a door with an equivalent fire rating to that of the wall or partition.
Tel:00 44 161 272 9333
Fax 00 44 161 272 9444
Please feel welcome to contact us over any matter that may occur to you. We are a friendly, approachable company and are more than willing to to help in any way.
We believe that thermal insulation, which will help to reduce your heating bills, is a key factor when considering insulated roller shutters. The lower the figure of the U-value of the equipment, the more effective the insulation. Westwood twin skin insulated roller shutters have a U-value of just 1.4 w/m2.